Difference between revisions of "MHS-5200A DDS Signal Generator"
Jump to navigation
Jump to search
Blwikiadmin (talk | contribs) |
Blwikiadmin (talk | contribs) |
||
Line 1: | Line 1: | ||
== Replace Wall-wart Power Supply == | == Replace Wall-wart Power Supply == | ||
− | * Wall warts put AC on the ground. | + | * Wall warts put AC on the ground. |
− | ** Fix it by replacing with an AC/DC linear supply | + | ** Fix it by replacing with an AC/DC linear supply |
+ | * Diodes backwards in image | ||
[[File:MHS-5200A_PwrSupply.png]] | [[File:MHS-5200A_PwrSupply.png]] |
Revision as of 14:03, 4 October 2020
Replace Wall-wart Power Supply
- Wall warts put AC on the ground.
- Fix it by replacing with an AC/DC linear supply
- Diodes backwards in image
- POWER XFMR 6.3Vct@1.2A 115V CHASSIS MOUNT w/LEADS/F-14X
- LF50ABV Voltage Regulator 5.0V 0.5A Positive
- 3x Aluminum Electrolytic Capacitors - Radial Leaded WCAP-ATG5 1200uF 16V 20% Radial
- 4x 1N5822-T Schottky Diodes & Rectifiers Vr/40V Io/3A T/R
- 2x 5mm terminal blocks
Simulation
6.8Vrms = 9.615V peak