Difference between revisions of "IOP16 Constants Unit"
Jump to navigation
Jump to search
Blwikiadmin (talk | contribs) |
Blwikiadmin (talk | contribs) |
||
Line 54: | Line 54: | ||
* Add to strobes and read mux | * Add to strobes and read mux | ||
+ | |||
+ | == Resources == | ||
+ | |||
+ | * Logic Cells: 74 | ||
+ | * Registers: 46 | ||
+ | * Memory Bits: 2048 | ||
+ | * M9Ks: 1 |
Revision as of 22:06, 14 April 2022
Contents
Constants ROM with Address Counter
A constants ROM can be used to store strings. This is useful for printing strings.
- Constants ROM
- 256-byte (max)
- Null terminated strings
- ROM "assembler"
- Address Counter
- Loadable with start address
- Auto-increment address
Programming
- Load start address (W)
- Read Data
Hook-up
- Add to Top Level VHDL code
Pins
- None - all internal
Signals
-- Decodes/Strobes ... signal w_ldConAdr : std_logic; signal w_rdConAdr : std_logic; ... -- Interfaces ... signal w_ConstsData : std_logic_vector(7 downto 0);
VHDL Instance
-- Constants Unit CONST_UNIT : entity work.ConstantsUnit port map ( i_clock => i_clk, i_dataIn => w_periphOut, i_ldStr => w_ldConAdr, i_rdStr => w_rdConAdr, o_constData => w_ConstsData );
Hook-up Strobes/Read Mux
- Add to strobes and read mux
Resources
- Logic Cells: 74
- Registers: 46
- Memory Bits: 2048
- M9Ks: 1