* Classic Octopus Tester | * Classic Octopus Tester | ||
** Based on [http://n5bl.org/pipermail/builders_n5bl.org/attachments/20150514/6b8107e1/attachment-0001.pdf design example (N5BL)] | ** Based on [http://n5bl.org/pipermail/builders_n5bl.org/attachments/20150514/6b8107e1/attachment-0001.pdf design example (N5BL)] | ||
− | |||
− | |||
− | |||
* Out of circuit component tester | * Out of circuit component tester | ||
** Useful for matching parts like diodes | ** Useful for matching parts like diodes | ||
Line 22: | Line 19: | ||
** Pot adjustments to set current (accommodate transformer and line voltage variances) | ** Pot adjustments to set current (accommodate transformer and line voltage variances) | ||
* 2 BNC jacks | * 2 BNC jacks | ||
− | |||
− | |||
− | |||
− | |||
* Plus, Minus Banana jacks | * Plus, Minus Banana jacks | ||
* AC powered | * AC powered | ||
Line 33: | Line 26: | ||
** 6.21 in W x 3.76 in D x 2 in H | ** 6.21 in W x 3.76 in D x 2 in H | ||
** Comes with screws and rubber feet | ** Comes with screws and rubber feet | ||
+ | |||
+ | === Scope Setup === | ||
+ | |||
+ | * Scope set to X-Y for voltage-vs-current measurement of part | ||
+ | ** Press button above time adjustment knob | ||
+ | ** Time Base XY | ||
+ | ** Look at scope pattern for device signature | ||
+ | ** Shows voltage/current phase relationships | ||
+ | ** 50 mS timebase | ||
+ | ** Connect to XY on scope (X=CH1, Y=CH2) | ||
+ | ** CH2 gets set to INVERT | ||
== X-Y Patterns == | == X-Y Patterns == |
Revision as of 18:24, 5 September 2021
Contents
Features
- Classic Octopus Tester
- Based on design example (N5BL)
- Out of circuit component tester
- Useful for matching parts like diodes
- In circuit component tester
- Test 2 units and compare signatures on scope
- Use 6.3V "filament" transformer
- 8.91V - Vpeak
- 17.82V - Vpeak-peak
- Typical transformer
- 1.38 in L, 2.38 in W, 1.38 in H
- 1mA, 10mA "scale" switch
- Pot adjustments to set current (accommodate transformer and line voltage variances)
- 2 BNC jacks
- Plus, Minus Banana jacks
- AC powered
- C13 jack with switch
- 1A Fuse
- Build into Bud Box CU-1945
- 6.21 in W x 3.76 in D x 2 in H
- Comes with screws and rubber feet
Scope Setup
- Scope set to X-Y for voltage-vs-current measurement of part
- Press button above time adjustment knob
- Time Base XY
- Look at scope pattern for device signature
- Shows voltage/current phase relationships
- 50 mS timebase
- Connect to XY on scope (X=CH1, Y=CH2)
- CH2 gets set to INVERT
X-Y Patterns
Resistors
- Resistor - slope line
- Slope = resistance value
- 1 mA setting = 8901 ohms, 1:1 slope
- 10 mA setting = 890 ohms, 1:1 slope
Capacitors
- Oval shape
- 0.3uF, 60 Hz, 8841 ohms
- 3uF, 60 Hz, 884 ohms
- 1 uF cap, 1mA selection
- 1 uF cap, 10mA selection
Zener
- 3.9V Zener
- 1 mA switch setting
- 10 mA switch setting
Schematics
- Adjust RV1/RV2 for total resistance (fixed resistor plus pot)
- 891 - 1 mA switch setting (RV2)
- 8910 - 10mA switch setting (RV1)
Cutouts on Bud Box CU-1945
Videos