Revision as of 19:26, 10 April 2022
Timer Unit
- Operates as a One-shot counter with single value
- Count uS, mSec or secs (allows for different resolutions)
- Write to count value starts timer
- Poll timer status
Address Value Read/Write Data 0 uSec Count Write 0-255 uS count - write starts timer 1 mSec Count Write 0-255 mS count - write starts timer 2 Sec Count Write 0-255 sec count - write starts timer 3 Not Used Write Not used 0-3 Status Read 1 = Count In progresss 0 = Done
Entity
-- ____________________________________________________________________________________ -- Timer Unit w_timerAdr <= '1' when (w_peripAddr(7 downto 2) = "000010") else '0'; timerUnit : entity work.TimerUnit port map ( -- Clock and Reset i_clk => i_clock, i_n_reset => w_resetClean_n, -- The key and LED on the FPGA card i_timerSel => w_timerAdr, i_writeStrobe => w_peripWr, i_regSel => w_peripAddr(1 downto 0), i_dataIn => w_peripDataFromCPU, o_dataOut => w_timerOut );
Resources (EP4CE15)
- Logic Cells: 89
- Registers: 49
- Memory Bits: 0