Difference between revisions of "Octopus Tester"
Jump to navigation
Jump to search
Blwikiadmin (talk | contribs) |
Blwikiadmin (talk | contribs) (→Zener) |
||
Line 52: | Line 52: | ||
=== Zener === | === Zener === | ||
+ | |||
+ | * 3.9V Zener | ||
+ | * 1 mA and 10 mA settings | ||
[[file:OctopusTester_Zener-01.png]] | [[file:OctopusTester_Zener-01.png]] |
Revision as of 16:27, 5 September 2021
Contents
Features
- Classic Octopus Tester
- Scope set to X-Y for voltage-vs-current measurement of part
- Look at scope pattern for device signature
- Out of circuit component tester
- Useful for matching parts like diodes
- In circuit component tester
- Test 2 units and compare signatures on scope
- Use 6.3V "filament" transformer
- 8.91V - Vpeak
- 17.82V - Vpeak-peak
- 1mA, 10mA "scale" switch
- Pot adjustments to set current (accommodate transformer and line voltage variances)
- 2 BNC jacks
- Timebase = XY
- Connect to XY on scope (X=CH1, Y=CH2)
- CH2 gets set to INVERT
- Plus, Minus Banana jacks
- AC powered
- C13 jack with switch
- 1A Fuse
- Build into Bud Box CU-1945
X-Y Patterns
Resistors
- Resistor - slope line
- Slope = resistance value
- 1 mA setting = 8901 ohms
- 10 mA setting = 890 ohms
Capacitors
- Oval shape
- 0.3uF, 60 Hz, 8841 ohms
- 3uF, 60 Hz, 884 ohms
- 1 uF caps, 1mA, 10mA selections
Zener
- 3.9V Zener
- 1 mA and 10 mA settings
Schematics
- Adjust RV2/RV2 for total resistance (fixed resistor plus pot)
- 891 - 1 mA switch setting
- 8910 - 10mA switch setting
Videos