Difference between revisions of "Octopus Tester"

From Land Boards Wiki
Jump to navigation Jump to search
Line 29: Line 29:
 
** 1A Fuse
 
** 1A Fuse
 
* Build into [https://www.mouser.com/ProductDetail/Bud-Industries/CU-1945?qs=YiMYZbOAr7eNf%252BiShkuUjg%3D%3D Bud Box CU-1945]
 
* Build into [https://www.mouser.com/ProductDetail/Bud-Industries/CU-1945?qs=YiMYZbOAr7eNf%252BiShkuUjg%3D%3D Bud Box CU-1945]
** 6.21 in L x 2 in W x 3.76 in H
+
** 6.21 in W x 3.76 in D x 2 in H
 
** Comes with screws and rubber feet
 
** Comes with screws and rubber feet
  

Revision as of 17:26, 5 September 2021

P1798-crop-720px.jpg

P1070804-crop-720px.jpg

Features

  • Classic Octopus Tester
  • Scope set to X-Y for voltage-vs-current measurement of part
    • Look at scope pattern for device signature
  • Out of circuit component tester
    • Useful for matching parts like diodes
  • In circuit component tester
    • Test 2 units and compare signatures on scope
  • Use 6.3V "filament" transformer
  • 1mA, 10mA "scale" switch
    • Pot adjustments to set current (accommodate transformer and line voltage variances)
  • 2 BNC jacks
    • Timebase = XY
    • Connect to XY on scope (X=CH1, Y=CH2)
    • CH2 gets set to INVERT
  • Plus, Minus Banana jacks
  • AC powered
    • C13 jack with switch
    • 1A Fuse
  • Build into Bud Box CU-1945
    • 6.21 in W x 3.76 in D x 2 in H
    • Comes with screws and rubber feet

X-Y Patterns

XY Patterns.PNG

Resistors

  • Resistor - slope line
    • Slope = resistance value
  • 1 mA setting = 8901 ohms, 1:1 slope
  • 10 mA setting = 890 ohms, 1:1 slope

OctopusTester Resistor.png

Capacitors

  • Oval shape
  • 0.3uF, 60 Hz, 8841 ohms
  • 3uF, 60 Hz, 884 ohms
  • 1 uF cap, 1mA selection

OctopusTester Cap 1uF-01.png

  • 1 uF cap, 10mA selection

OctopusTester Cap 1uF-02.png

Zener

  • 3.9V Zener
  • 1 mA switch setting

OctopusTester Zener-01.png

  • 10 mA switch setting

OctopusTester Zener-02.png

Schematics

OctopusTester SCHEM.PNG

  • Adjust RV2/RV2 for total resistance (fixed resistor plus pot)
    • 891 - 1 mA switch setting
    • 8910 - 10mA switch setting

Cutouts on Bud Box CU-1945

OctopusTester FRONT-BACK.PNG

Videos