Octopus Tester
Contents
Features
- Classic Octopus Tester
- Scope set to X-Y for voltage-vs-current measurement of part
- Look at scope pattern for device signature
- Out of circuit component tester
- Useful for matching parts like diodes
- In circuit component tester
- Test 2 units and compare signatures on scope
- Use 6.3V "filament" transformer
- 8.91V - Vpeak
- 17.82V - Vpeak-peak
- 1mA, 10mA switch
- Pot adjustments to set current (transformer variances)
- 2 BNC jacks
- Timebase = XY
- Connect to XY on scope (X=CH1, Y=CH2)
- CH1 gets set to INVERT
- Plus, Minus Banana jacks
- AC powered
- C13 jack with switch
- Fuse
- Build into Bud Box CU-1945
X-Y Patterns
Resistors
- Resistor - slope line
- Slope = resistance value
- 1 mA setting = 8901 ohms
- 10 mA setting = 890 ohms
Capacitors
- Oval shape
- 0.47uF, 60 Hz = 5643 ohms
- 1uF, 60 Hz = 2652 ohms
- 3.3uF, 60 Hz = 803 ohms
Schematics
- Adjust RV2/RV2 for total resistance (fixed resistor plus pot)
- 891 - 1 mA switch setting
- 8910 - 10mA switch setting
Videos