[[file:P1798-crop-720px.jpg]]
+
== Design ==
  
[[file:P1070804-crop-720px.jpg]]
+
* [[Mini360 Buck Converter]]
 
 
== Features ==
 
 
 
* Classic Octopus Tester
 
** Based on [http://n5bl.org/pipermail/builders_n5bl.org/attachments/20150514/6b8107e1/attachment-0001.pdf design example (N5BL)]
 
* Scope set to X-Y for voltage-vs-current measurement of part
 
** Look at scope pattern for device signature
 
** Shows voltage/current phase relationships
 
* Out of circuit component tester
 
** Useful for matching parts like diodes
 
* In circuit component tester
 
** Test 2 units and compare signatures on scope
 
* Use 6.3V "filament" transformer
 
** 8.91V - Vpeak
 
** 17.82V - Vpeak-peak
 
** [https://www.mouser.com/ProductDetail/Triad-Magnetics/F-13X?qs=b1anAsPanWz99oSBmlGHww%3D%3D Typical transformer]
 
*** 1.38 in L, 2.38 in W, 1.38 in H
 
* 1mA, 10mA "scale" switch
 
** Pot adjustments to set current (accommodate transformer and line voltage variances)
 
* 2 BNC jacks
 
** Timebase = XY
 
** Connect to XY on scope (X=CH1, Y=CH2)
 
** CH2 gets set to INVERT
 
* Plus, Minus Banana jacks
 
* AC powered
 
** C13 jack with switch
 
** 1A Fuse
 
* Build into [https://www.mouser.com/ProductDetail/Bud-Industries/CU-1945?qs=YiMYZbOAr7eNf%252BiShkuUjg%3D%3D Bud Box CU-1945]
 
** 6.21 in W x 3.76 in D x 2 in H
 
** Comes with screws and rubber feet
 
 
 
== X-Y Patterns ==
 
 
 
[[file:XY_Patterns.PNG]]
 
 
 
=== Resistors ===
 
 
 
* Resistor - slope line
 
** Slope = resistance value
 
* 1 mA setting = 8901 ohms, 1:1 slope
 
* 10 mA setting = 890 ohms, 1:1 slope
 
 
 
[[file:OctopusTester_Resistor.png]]
 
 
 
=== Capacitors ===
 
 
 
* Oval shape
 
* 0.3uF, 60 Hz, 8841 ohms
 
* 3uF, 60 Hz, 884 ohms
 
* 1 uF cap, 1mA selection
 
 
 
[[file:OctopusTester_Cap_1uF-01.png]]
 
 
 
* 1 uF cap, 10mA selection
 
 
 
[[file:OctopusTester_Cap_1uF-02.png]]
 
 
 
=== Zener ===
 
 
 
* 3.9V Zener
 
* 1 mA switch setting
 
 
 
[[file:OctopusTester_Zener-01.png]]
 
 
 
* 10 mA switch setting
 
 
 
[[file:OctopusTester_Zener-02.png]]
 
 
 
== Schematics ==
 
 
 
[[file:OctopusTester_SCHEM.PNG]]
 
 
 
* Adjust RV1/RV2 for total resistance (fixed resistor plus pot)
 
** 891 - 1 mA switch setting (RV2)
 
** 8910 - 10mA switch setting (RV1)
 
 
 
== Cutouts on Bud Box CU-1945 ==
 
 
 
[[FILE:OctopusTester_FRONT-BACK.PNG]]
 
 
 
== Videos ==
 
 
 
<video type="youtube">Gwo3pEH7hUE</video>
 
 
 
<video type="youtube">EaipFdk67HE</video>
 
 
 
<video type="youtube">a1HgshaEbaw</video>
 
 
 
<video type="youtube">5ppFpU5K2WY</video>
 
 
 
<video type="youtube">R95f9gGFUGI</video>
 

Revision as of 22:23, 5 September 2021