Difference between revisions of "Frequency Counter"

From Land Boards Wiki
Jump to navigation Jump to search
Line 24: Line 24:
  
 
* [https://www.aliexpress.com/item/32833340145.html?spm=a2g0o.productlist.0.0.68406390LYz5Rw&algo_pvid=0bbf736e-a88e-4ac7-9adc-03df1259669a&algo_expid=0bbf736e-a88e-4ac7-9adc-03df1259669a-0&btsid=0bb0622a16017274930362968ef528&ws_ab_test=searchweb0_0,searchweb201602_,searchweb201603_ BNC connector - female chassis mount]
 
* [https://www.aliexpress.com/item/32833340145.html?spm=a2g0o.productlist.0.0.68406390LYz5Rw&algo_pvid=0bbf736e-a88e-4ac7-9adc-03df1259669a&algo_expid=0bbf736e-a88e-4ac7-9adc-03df1259669a-0&btsid=0bb0622a16017274930362968ef528&ws_ab_test=searchweb0_0,searchweb201602_,searchweb201603_ BNC connector - female chassis mount]
* 5.1mm Chassis mount power connector
+
* [https://www.ebay.com/itm/USA-12-PCS-5-5-MMX-2-1-MM-CHASSIS-PANEL-MOUNT-FEMALE-POWER-JACK-SOCKETS-NEW/264838025913?ssPageName=STRK%3AMEBIDX%3AIT&_trksid=p2057872.m2749.l2649 5.1mm Chassis mount power connector]
 
** 7-9V in
 
** 7-9V in
 
* Right angle header pins pointing to inside of card
 
* Right angle header pins pointing to inside of card

Revision as of 14:22, 3 October 2020

FreqXounter-Kit-Assembled-02.PNG

Features

Case

  • P-Touch white on black labels

FreqCounterLabels.jpg

Plastic 100x60x25mm-720px.jpg

Rework - Add Pre-Amp

  • Re-uses extra HF transistor that would have been used by crystal tester oscillator
  • AC coupled input
  • Based on

Pre-Amp schematic

FreqCounter PreAmp Schematic.PNG

When building kit, do not install

FreqCounter DoNotInstallParts.PNG

Cuts/Jumpers

  • Four cuts
    • Blue = 1 front side cut
    • Green = 3 back side cuts
  • Jumpers Red

FreqCounter Rework PCB Front.PNG

  • Green = Back side cuts

FreqCounter Rework PCB Back.png

  • Short etch on one cut

FreqCounter Rework-Cuts-Back.PNG

  • Details of preamp input pin

FreqCounter Rework-06.PNG

  • With parts

FreqCounter Rework-07.PNG

  • Wire on back

FreqCounter Rework Wires Back.PNG

Testing

FreqCounter InCase.jpg

  • 4.9152 MHz crystal
  • Scope frequency counter shows 4.19520 MHz
  • Freq Counter displays 4.9747 MHz
  • Difference = 500 Hz or 0.1% accuracy
  • Can only adjust the variable capacitor in narrow range

Reviews / Builds