Difference between revisions of "Frequency Counter"
Jump to navigation
Jump to search
Blwikiadmin (talk | contribs) |
Blwikiadmin (talk | contribs) |
||
Line 17: | Line 17: | ||
* P-Touch white on black labels | * P-Touch white on black labels | ||
− | [[File: | + | [[File:FreqCounter-P181-720px.jpg]] |
* [https://www.ebay.com/itm/5pcs-100x60x25mm-Black-Plastic-Electronic-Project-Box-Enclosure-Instrument-Case/184015618380?hash=item2ad82f814c:g:iewAAOSwt6RduhdS 100x60x25mm Black Plastic Electronic Project Box Enclosure Instrument Case] - Inexpensive plastic case | * [https://www.ebay.com/itm/5pcs-100x60x25mm-Black-Plastic-Electronic-Project-Box-Enclosure-Instrument-Case/184015618380?hash=item2ad82f814c:g:iewAAOSwt6RduhdS 100x60x25mm Black Plastic Electronic Project Box Enclosure Instrument Case] - Inexpensive plastic case |
Revision as of 13:50, 1 November 2020
Contents
Features
- Original Design by DL4YHF
- Frequency range: 1 Hz-50 MHz
- Crystal Test Range: 4 MHz-48 MHz - Replaced with pre-amp circuit
- PCB size:8*5.3cm
- Fits in 100 x 60 x 25 mm enclosure
- Source - AliExpress Frequency Counter - Very inexpensive
- PIC-freq.counter-modification
- Mods to replace crystal checker with sensitive pre-amp
Built into case
- P-Touch white on black labels
- 100x60x25mm Black Plastic Electronic Project Box Enclosure Instrument Case - Inexpensive plastic case
- Plastic Waterproof Cover Electronic Project Instrument Enclosure DIY Box Case Junction Box Housing 100 x 60 x 25 mm Black
- 7-9V in
- Right angle header pins pointing to inside of card
- 4-40 x 3/16” Machine Screws
- 4-40 Standoffs
Rework - Add Pre-Amp
- Re-uses extra HF transistor that would have been used by crystal tester oscillator
- AC coupled input
- Based on
Pre-Amp schematic
When building kit, do not install
Cuts/Jumpers
- Four cuts
- Blue = 1 front side cut
- Green = 3 back side cuts
- Jumpers Red
- Green = Back side cuts
- Short etch on one cut
- Details of preamp input pin
- With parts
- Wire on back
Testing
- 4.9152 MHz crystal oscillator
- Scope frequency counter shows 4.19520 MHz
- Freq Counter displays 4.9747 MHz
- Difference = 500 Hz or 0.1% accuracy
- Can only adjust the variable capacitor in narrow range
- Freq = 25,000 MHz - measured = 24.997 MHz
- Error = 3 KHz / 25,000 KHz = 0.012%
- Freq = 10.000 Hz - measured = 9.999 Hz = .01% error
Firmware Mods